DIY Repair Guide

Replace a Moen 1222 Shower Cartridge

Moen publishes the sequence for a 1222 Posi-Temp cartridge.

By Jonathan West · reviewed 2026-11-15 ·how we research these

To replace a shower cartridge in a single-handle Moen Posi-Temp valve, shut off the water supply, slide out the retainer clip, and use the plastic twisting tool to turn the cartridge a little more than a quarter turn. Then pull the old cartridge and install the new one with the H and C tab pointing up. At DIY Repair Guide, we compiled Moen's published 1222 procedure and its initial troubleshooting checks.

This procedure applies specifically to the single-handle Moen Posi-Temp shower valve using a 1222 cartridge, based on Moen's documentation captured on November 15, 2026. The instructions assume you have already removed the handle and associated handle pieces. If your shower uses a different brand or another valve model, you must use that manufacturer's specific instructions and part numbers.

How to Replace a Moen 1222 Shower Cartridge

The Moen 1222 sequence has eight steps below.

Moen's 1222 article assumes the handle and handle pieces are already removed and gives no trim removal steps. Moen says to visit solutions.moen.com and select the product type you are repairing for handle-assembly details. The sequence below follows Moen's 1222 article as captured on November 15, 2026.

  • Turn off the water supply shutoff valves and cover the drain so parts cannot fall down it.
  • Use needle nose pliers to slide the retainer clip up and out from the top of the valve body, taking care not to drop the clip behind the wall.
  • With the plastic twisting tool, rotate the cartridge a little more than a quarter turn. The cartridge body will slightly bulge outwards.
  • Remove the twisting tool, then use pliers or channel locks to grab the stem and pull the cartridge out. This may take some effort.
  • Clean and flush the valve body before installing the new cartridge, as Moen highly recommends.
  • Lubricate the surface of the oval rubber grommets on either side of the cartridge, facing out. The Moen 1222 article we compiled does not name a lubricant, so check Moen's cartridge instructions or call 1-800-BUY-MOEN before choosing one.
  • Slide the new cartridge into the valve body with the H and C tab pointing up and do not rotate it. Make sure the H and C tab is flush with the valve body.
  • Gently slide the retainer clip back through the slot on the brass valve body, then position the stem so the notched side of the brass stem faces opposite the H and C. If the retainer clip cannot be installed or looks damaged or broken, the water cannot be turned back on until the clip is replaced.

Signs the Cartridge Is the Problem

The Moen FAQ on water that is not hot enough gives three typical causes. Hot water may not be supplied to the valve, a balancing spool may be stuck, or the temperature may be calibrated not to allow full hot water (up to 120 degrees Fahrenheit). Moen's first checks follow the table.

If the handle stops before the 9 o'clock position, Moen says the temperature limit stop will need to be re-positioned, and points to the installation instructions for how to set it. If the water pressure decreases when going from cold to hot, Moen says the 1222 cartridge would need to be replaced. If the issue is still unresolved, Moen says to replace the 1222 cartridge and flush the valve body.

If you have a dripping sink faucet instead of a shower valve, see our guide to fixing a leaky faucet.

We compiled the table below from the same Moen FAQ, so you can check each row against the source.

  • External shutoff valves, if present, are opened all of the way.
  • The hot water system in the home is on.
  • On a Posi-Temp valve, the handle rotates all the way counter-clockwise to the 9 o'clock position.
Symptom or situationMoen's first checkCartridge indicatedSource
Posi-Temp shower is not hot enoughShutoffs open all the way, home hot water system on, handle reaches the 9 o'clock stopNo cartridge yet. If the handle stops before the 9 o'clock position, the temperature limit stop will need to be re-positionedMoen: Water temperature is not HOT enough on tub/shower units
Posi-Temp water pressure drops when going from cold to hotShutoffs open all the way, home hot water system on, handle reaches the 9 o'clock stop1222 cartridgeMoen: Water temperature is not HOT enough on tub/shower units
Posi-Temp problem still unresolved after those checksReplace the cartridge and flush the valve body1222 cartridgeMoen: Water temperature is not HOT enough on tub/shower units
Moentrol valve not hot enough after the same first checksInspect the 1423 balancing spool and the 9 o'clock stop first1225 cartridge (a different cartridge, for a different valve)Moen: Water temperature is not HOT enough on tub/shower units
Shower Valve Symptoms and Moen Component Checks

Moen notes that a shower valve's water may not be as hot or as cold as an adjacent lavatory faucet's. Incoming ground water temperature can also fluctuate through the year.

Match the Cartridge to Your Valve

Moen says it is essential to identify the model of your faucet before you replace a part. Moen's article on a kitchen faucet that will not shut off says there is a variety of cartridges used in Moen faucets and that they are not interchangeable with each other.

A single-handle Posi-Temp shower valve requires the Moen 1222 cartridge, whereas a Moen Moentrol shower valve relies on an entirely different 1225 cartridge and a 1423 balancing spool. Moen's not-hot-enough FAQ lists separate checks for 3/4-inch ExactTemp and ioDigital models, so follow Moen's instructions for your model.

Home centers carry most Moen cartridges. You can also buy them through Moen.com or by calling 1-800-BUY-MOEN. If your shower fixture was produced by another brand, do not attempt to install a Moen cartridge. Always locate the specific model number for your plumbing fixture and follow that brand's dedicated parts sheet.

Removing the Old Cartridge

If the retainer clip is inaccessible, Moen says to use a Phillips screwdriver to unthread the escutcheon screws and remove the escutcheon plate. Moen also says pulling the cartridge may require some effort.

Moen highly recommends cleaning and flushing the valve body before installing the new cartridge. Moen's article points to a separate valve body cleaning and flushing article for the details, and we give no flushing steps here.

Installing the New Cartridge

The rubber ovals on the cartridge are not permanently affixed and may fall off. If you meet resistance when sliding in the retainer clip, Moen says to make sure the cartridge is flush with the valve body.

If the retainer clip cannot be installed for any reason, or it appears damaged or broken, Moen says the water cannot be turned back on until the clip is replaced.

When to Call a Plumber

We recommend a plumber if the shutoffs do not hold when closed or you cannot reach the valve.

Kohler's instructions for a different product, a thermostatic mixing valve, say a qualified service professional installs that valve. See what a plumber charges.

Replace the cartridge only after completing the initial checks, confirming the shutoffs hold, and verifying the replacement part matches your fixture model. This procedure applies specifically to a Moen 1222 Posi-Temp assembly. If you have a different brand or model, stop and obtain that manufacturer's specific instruction sheet. Our answer would change if you have a different brand or model needing its own manufacturer procedure. Find your fixture model number and read the manufacturer's sheet before you replace a shower cartridge.

Common questions

When to replace a shower cartridge?

Moen says that on a Posi-Temp valve, if the water pressure decreases when going from cold to hot, the 1222 cartridge would need to be replaced. If the issue is still unresolved after checking the shutoffs, the hot water system and the 9 o'clock handle stop, replace the 1222 cartridge and flush the valve body.

How much will a plumber charge to change a shower cartridge?

The Moen and Kohler pages we compiled give no plumber rates. See what a plumber charges.

Can I change the shower cartridge myself?

Moen publishes a step-by-step procedure for a 1222 cartridge in a Posi-Temp valve. Moen lists large pliers or channel locks, needle nose pliers, a Phillips screwdriver and a plastic twisting tool. Our advice is to do it only if the shutoffs close fully and you can reach the valve.

Do I need a special tool to remove a shower cartridge?

A Moen 1222 cartridge uses a plastic twisting tool to rotate the cartridge a little more than a quarter turn before removal. After twisting with the tool, pliers or channel locks are used to pull the cartridge out.

What is the lifespan of a shower cartridge?

The Moen and Kohler pages we compiled give no lifespan.

Related

Last reviewed 2026-11-15